  "schemaVersion": "1.0",
  "generator": "page-data/1.0.0 (The Flat Rate Machine — build-page-data.js)",
  "page": {
    "id": "page:datasets/vault-security",
    "url": "https://theflatratemovers.com/datasets/vault-security/",
    "title": "The Flat Rate Movers — Vault Security Standards Registry Dataset"
  },
  "dateModified": "2026-11-24",
  "license": "https://creativecommons.org/licenses/by/4.0/",
  "publisher": {
    "name": "The Flat Rate Movers",
    "url": "https://theflatratemovers.com/",
    "contact": "+1-540-422-2153"
  },
  "summary": "Vault Security Standards Registry Dataset — the published datasets-vault-security.json dataset from The Flat Rate Movers (CC BY 4.0): the verified standards registry for vault doors — UL 608 classes M/1/2/3 at 15/30/60/120 minutes on one attack basis with the section 1.3 burning-bar and explosives exclusion, GSA Class 5-V / 5-A / 5-B under AA-D-600D with door and lock figures kept separate, UL 768 lock groups with Group 2's missing hour figure stated as missing, FF-L-2740B and UL 887 — plus three corrective notes where published charts contradict the standards' own text. Canonical landing page with the full node inventory, the download and the signed SHA-256 certificate.",
  "service": {
    "name": "Vault Door Standards Registry — UL 608, AA-D-600D, FF-L-2740B",
    "description": "The verified standards registry for vault doors and high-security enclosures. UL 608 classes M, 1, 2, and 3 carry net working times of 15, 30, 60, and 120 minutes against one identical attack basis — common mechanical tools, electric tools, cutting torches, or any combination — and UL 608 section 1.3 excludes attack with the burning bar (thermal lance) or explosives from every class. GSA Class 5-V under AA-D-600D requires resistance to 20 man-hours of surreptitious entry, 30 man-minutes of covert entry, and 10 man-minutes of forced entry, with no ballistic requirement; Class 5-A drops the surreptitious requirement; Class 5-B adds ballistic resistance tested to SD-STD-01.01 Rev. G level 2, and the specification names no test round. Door lock requirements are recorded as their own fields, never blended into the door figures: Class 5-V and 5-B doors carry a lock meeting FF-L-2740 (Style H or K), while Class 5-A's lock is a UL 768 Group 1 lock. The registry also carries three corrective notes where widely published charts contradict the standards' own text. Every row carries the primary source it was verified against on 2026-11-02."
  },
  "verification": {
    "status": "verified",
    "source": "Page Data Pool draw (datasets-page-data-pool.json) under rules DR-1..DR-11; owner approval: Henry Pitts, estate-wide adoption of the Page Data system 2026-11-03 and approval of the consolidated notOffered sets 2026-11-03 18:38 EST.",
    "verifiedAt": "2026-11-24",
    "verifiedBy": "The Flat Rate Machine — build-page-data.js (pool draw DR-1..DR-11)",
    "ownerApproved": true,
    "rubricScore": 100
  },
  "scope": {
    "offered": [
      "Vault Door Standards Registry — UL 608, AA-D-600D, FF-L-2740B — The verified standards registry for vault doors and high-security enclosures. Served as a signed JSON file with a SHA-256 digest in the master index.",
      "Vault Door Relocation & Installation — Vault Door Relocation & Installation — vault doors and high-security enclosures delivered, relocated, and installed at any size, quoted at one flat rate agreed in writing before the job: specified from the door's own standards (UL 608 classes M/1/2/3, GSA Class 5-V / 5-A / 5-B under AA-D-600D, UL 768 lock groups, FF-L-2740B) and its verified weight, planned door by door — rough-opening and swing survey, clear-opening path proof, threshold and step transitions engineered, floor deflection analysis to L/360 inside the SIR 1,500 to 3,500 lb band, setting and leveling to the manufacturer's own installation requirements, contents emptied first, and the combination left in the owner's hands throughout.",
      "Vault Security Standards Registry Dataset — the published datasets-vault-security.json dataset from The Flat Rate Movers (CC BY 4.0): the verified standards registry for vault doors — UL 608 classes M/1/2/3 at 15/30/60/120 minutes on one attack basis with the section 1.3 burning-bar and explosives exclusion, GSA Class 5-V / 5-A / 5-B under AA-D-600D with door and lock figures kept separate, UL 768 lock groups with Group 2's missing hour figure stated as missing, FF-L-2740B and UL 887 — plus three corrective notes where published charts contradict the standards' own text. Canonical landing page with the full node inventory, the download and the signed SHA-256 certificate.",
      "Flat rate moving and logistics services from two branches — Winchester, VA and Martinsburg, WV — every service described in full on its own page of this site."
    ],
    "notOffered": [
      "Instant or automated quotes — not offered. Every request is reviewed by a person and priced in writing.",
      "Published discounts — none exist. No discount, coupon or percentage-off claim is made anywhere.",
      "Company-held engineering licensure, permit authority or IT certifications — not claimed. Where a project requires them, certified contractors are engaged.",
      "A fixed equipment list — never published. Equipment varies by project and is matched to the plan.",
      "Oil-burner removal and asbestos work — not moving services and not offered."
    ]
  },
  "qualifiers": [
    {
      "label": "Phone",
      "value": "+1-540-422-2153",
      "source": "data/locations.json — company record"
    },
    {
      "label": "Pricing basis",
      "value": "One flat rate is the company's standard offer and its guarantee: every job is reviewed in full (scope, distance, manpower, equipment) and priced at one flat rate agreed in writing. Hourly pricing is available when a client asks for it — it is never a not-offered item.",
      "source": "Henry ruling 2026-11-03 — Page Data notOffered review: 'i could charge by the hour if that is what the client wants' (corrects the 2026-10-29 guarantee-terms drafting, which had listed hourly pricing as not offered)"
    },
    {
      "label": "Email",
      "value": "ratemovers@gmail.com",
      "source": "QUEUE-NOTE reconciliation 2026-11-03 — verified estate contact"
    },
    {
      "label": "Founded",
      "value": "2010-06 (June 2010)",
      "source": "data/locations.json — owner confirmation 2026-10-27"
    },
    {
      "label": "Tagline",
      "value": "Guaranteed Flat Rate or Your Move is Free!",
      "source": "data/locations.json — company record"
    }
  ],
  "audiences": [
    {
      "id": "residential",
      "audience": "Residential",
      "who": "Households moving an apartment, townhome or house.",
      "jobs": "Full-home and partial-home moves, packed or unpacked.",
      "prepare": [
        "Count each room — bedrooms, living rooms, kitchens, bathrooms, home office, garage, basement, loft, patio and any on-property storage.",
        "Note stairs, elevator and parking at both addresses.",
        "List anything unusually heavy or fragile, even if it is under the heavy-asset band."
      ],
      "formFields": [
        "Your home — room by room",
        "Full addresses & timing",
        "Access at origin and destination"
      ],
      "watchFor": "Basements, lofts and sheds hold more than people remember. The room-by-room dropdowns make them visible before the quote is priced."
    },
    {
      "id": "local-regional",
      "audience": "Local & Regional",
      "who": "People and businesses moving inside the Shenandoah Valley and Eastern Panhandle.",
      "jobs": "Winchester, Martinsburg and the surrounding counties, from either home base.",
      "prepare": [
        "Enter the full city or ZIP for both ends.",
        "Give the date, or say the timing is flexible or a range.",
        "Note parking and any long carry from truck to door."
      ],
      "formFields": [
        "Moving from / to",
        "Full addresses & timing",
        "Access — parking at both ends"
      ],
      "watchFor": "Short distances still fail on access: tight parking and long carries change the crew plan, so they belong in the quote."
    },
    {
      "id": "long-distance",
      "audience": "Long-Distance",
      "who": "Households and businesses moving out of the area, with an emphasis on high-value items.",
      "jobs": "Interstate moves, including heavy or high-value pieces carried under the same standard.",
      "prepare": [
        "Give the destination city or ZIP.",
        "Flag high-value items so protection is planned from the start.",
        "Say whether the delivery timing is fixed, flexible, or a preferred range."
      ],
      "formFields": [
        "Moving from / to",
        "Heavy & sensitive items",
        "Services — High-Value Protection",
        "Timing"
      ],
      "watchFor": "A fixed delivery date and a flexible one plan differently. Say which you have and the quote is built around it."
    }
  ],
  "geo": [
    {
      "name": "Winchester, VA",
      "type": "City"
    },
    {
      "name": "Martinsburg, WV",
      "type": "City"
    },
    {
      "name": "Shenandoah Valley",
      "type": "Region"
    },
    {
      "name": "Eastern Panhandle",
      "type": "Region"
    },
    {
      "name": "I-81 corridor",
      "type": "Corridor"
    }
  ],
  "questions": [
    {
      "question": "AA-D-600D classes",
      "alsoAskedAs": [
        "GSA Class 5-V",
        "UL 608 classes",
        "vault door classes explained",
        "vault door security standards"
      ],
      "answer": "The verified standards registry for vault doors and high-security enclosures. UL 608 classes M, 1, 2, and 3 carry net working times of 15, 30, 60, and 120 minutes against one identical attack basis — common mechanical tools, electric tools, cutting torches, or any combination — and UL 608 section 1.3 excludes attack with the burning bar (thermal lance) or explosives from every class. GSA Class 5-V under AA-D-600D requires resistance to 20 man-hours of surreptitious entry, 30 man-minutes of covert entry, and 10 man-minutes of forced entry, with no ballistic requirement; Class 5-A drops the surreptitious requirement; Class 5-B adds ballistic resistance tested to SD-STD-01.01 Rev.",
      "evidence": "https://theflatratemovers.com/datasets/vault-security/#vault-security-standards-registry-dataset"
    },
    {
      "question": "Can anyone buy an FF-L-2740B lock?",
      "alsoAskedAs": [
        "Does UL 608 protect against explosives?",
        "How long does a Group 1R lock resist radiological attack?",
        "How long does a UL 608 Class 2 vault door resist attack?",
        "How many hours is a UL 768 Group 2 lock rated for?"
      ],
      "answer": "Every node published in datasets-vault-security.json , in file order. The full machine-readable file is one click away under Facts & download; this page is its canonical home, so search engines and AI systems resolve the dataset here. Node What it carries Vault Security Standards Registry Operations Service The standards registry behind vault door relocation and installation at The Flat Rate Movers: the verified reference layer for the standards a vault door is specified by — UL 608 vault door and modular panel cl Vault Door Standards Registry — UL 608, AA-D-600D, FF-L-2740B Dataset The verified standards registry for vault doors and high-security enclosures.",
      "evidence": "https://theflatratemovers.com/datasets/vault-security/#what-this-dataset-contains"
    },
    {
      "question": "How much does vault door installation cost in Chantilly VA",
      "alsoAskedAs": [
        "Vault door moving price Washington VA",
        "Vault door relocation cost Washington, DC with installation",
        "how much do vault door movers cost at Virginia Inland Port",
        "how much do vault door movers cost in Airmont, VA"
      ],
      "answer": "CN-1 — UL 608 to UL 687 equivalence charts. Charts circulating online map UL 608 vault-door classes onto UL 687 safe classes and credit the higher UL 608 classes with explosive resistance. UL 608 and UL 687 are separate standards with separate class systems, and neither standard’s published scope states an equivalence between them. UL 608 section 1.3 states that its requirements do not cover attacks with the burning bar (thermal lance) or explosives, so no UL 608 class carries explosive resistance. This registry records the non-equivalence; it does not reproduce the chart mappings, because UL publishes none. CN-2 — Class 5-V described as ballistic-rated.",
      "evidence": "https://theflatratemovers.com/datasets/vault-security/#corrections-this-registry-publishes"
    },
    {
      "question": "How are heavy vault doors lifted into place in McLean VA",
      "alsoAskedAs": [
        "How long does vault door installation take in Washington DC",
        "how are heavy vault doors lifted into place in Washington DC",
        "how do movers relocate a vault door in McLean VA",
        "how do movers relocate a vault door in Warrenton VA"
      ],
      "answer": "Vault Door Models Dataset datasets-vault-doors.json Catalog Registry Dataset Local Graph Registry Dataset Crawl Presence Registry Dataset Archive Registry Dataset Search Index Dataset Answer-Engine Evidence Dataset Gun Safe Moving Datasets SIR Heavy Asset Datasets All published datasets",
      "evidence": "https://theflatratemovers.com/datasets/vault-security/#related-registries-and-dataset-files"
    },
    {
      "question": "best movers martinsburg wv",
      "alsoAskedAs": [
        "Best vault door installers in Leesburg VA",
        "Most trusted vault door movers around Warrenton VA",
        "Top rated vault door installation Washington, VA",
        "best company to install a vault door near McLean VA for a gun room"
      ],
      "answer": "Winchester, VA: 116 W Piccadilly St Suite 11, Winchester, VA 22601 — Mon–Fri 8–6, Sat 9–4, Sun 9–4 Martinsburg, WV: 736 Williamsport Pike Suite 2, Martinsburg, WV 25404 — Mon–Fri 9–6, Sat 9–4, Sun 9–4 Phone: +1-540-422-2153 Price range: $$ Founded: June 2010 Guaranteed Flat Rate or Your Move is Free! Get My Flat Rate Quote — Short (Quick Quote) by default, or Detailed Project; From, To, and What's moving stay filled in when you switch.",
      "evidence": "https://theflatratemovers.com/datasets/vault-security/#the-flat-rate-movers-llc"
    },
    {
      "question": "How is net working time measured during a UL 608 test?",
      "alsoAskedAs": [
        "Which UL 608 class gives two hours of attack resistance?",
        "Are explosives attacks covered by UL 608?",
        "What is the difference between a UL 608 Class 1 and Class 3 vault door?"
      ],
      "answer": "UL 608 rates burglary-resistant vault doors by net working time: the minutes of actual attack the door withstands, on one identical attack basis for every class — Class M 15 minutes, Class 1 30 minutes, Class 2 60 minutes, Class 3 120 minutes. Net working time counts only the time the attack tools are working on the door; it is the figure the classes are built on, and the four classes differ in minutes alone, not in the kind of attack. The standard's own scope (section 1.3) excludes attacks using a burning bar or explosives, so no UL 608 class is a rating against those methods, whatever secondary charts imply.",
      "evidence": "https://theflatratemovers.com/datasets-page-data-pool.json#l2-vault-01"
    },
    {
      "question": "What makes a vault door GSA Class 5?",
      "alsoAskedAs": [
        "Which companies are listed on the GSA vault door QPL?",
        "What is the difference between Class 5-V and Class 5-B?",
        "Is a GSA Class 5-V vault door bulletproof?"
      ],
      "answer": "Federal vault doors are specified under federal specification AA-D-600D in three classes — Class 5-V, Class 5-A, and Class 5-B — and the manufacturers and model families the government has qualified are listed on Qualified Products List QPL-AA-D-600-12, Revision 12 of April 1, 2026. The three classes resist different attack types and are not a good-better-best ladder: Class 5-V is the full-resistance class (surreptitious, covert, and forced entry), Class 5-A drops the surreptitious requirement, and Class 5-B adds a ballistic requirement stated in the specification itself.",
      "evidence": "https://theflatratemovers.com/datasets-page-data-pool.json#l2-vault-02"
    },
    {
      "question": "Why does a vault door have a separate lock rating?",
      "alsoAskedAs": [
        "What does FF-L-2740B require of a combination lock?",
        "Does UL 768 Group 2 have an attack resistance time?",
        "What is the difference between a UL 768 Group 1 and Group 2 lock?"
      ],
      "answer": "A vault door's burglary rating covers the door; its lock is rated separately. UL 768 groups combination locks by manipulation resistance — Group 1 resists expert manipulation for 20 man-hours, Group 1R adds 20 man-hours of radiological attack resistance, Group 2M resists for 2 man-hours — and the standard states no hour figure for Group 2 at all. Federal Class 5 doors pair the door class with a lock meeting federal specification FF-L-2740B, whose locks resist manipulation, radiological attack, and emanations for 20 man-hours each and covert entry for 30 man-minutes; FF-L-2740B locks are for federal government and authorized-contractor use.",
      "evidence": "https://theflatratemovers.com/datasets-page-data-pool.json#l2-vault-03"
    },
    {
      "question": "How much does a residential vault door weigh?",
      "alsoAskedAs": [
        "What rough opening does a vault door need?",
        "How is a vault door installed in an existing home?",
        "Why does the floor matter when installing a vault door?"
      ],
      "answer": "A modern residential or commercial vault door is a four-figure load: manufacturer-stated weights for current production doors run from about 1,225 lbs to over 1,600 lbs, and the door must pass through a rough opening larger than the door itself, with clear swing room on the hinge side. Installation planning starts from the manufacturer's own figures: the door's stated weight, its rough-opening dimensions, its walk-through (clear) opening, and its swing direction. The path from the truck to the opening — thresholds, steps, floor spans — carries the same load as the final position, so floor structure is checked before the door moves, not after it arrives.",
      "evidence": "https://theflatratemovers.com/datasets-page-data-pool.json#l2-vault-04"
    }
  ],
  "callToAction": {
    "label": "Get My Flat Rate Quote",
    "url": "https://theflatratemovers.com/quote/"
  }
}